Effect of Internal Recycle on Nitrogen Removal in a Novel Anoxic/oxic Integrated Biofilm Reactor Treating Low C/N Ratio Domestic Sewage

机译:内部循环对新型处理低C / N比生活污水的缺氧/缺氧集成生物膜反应器中氮去除的影响

获取原文
获取原文并翻译 | 示例

摘要

In this work, a novel integrated anoxic/oxic biofilm reactor was proposed to treat rural domestic sewage with low carbon to nitrogen (C/N) ratio. Effects of internal recycle (R) on pre-denitrification and biomass production in anoxic zones of the integrated reactor were mainly investigated to tap the potentials of efficiency and economy. The experimental results obtained during a 98-day period showed that: the nitrogen removal efficiencies of 69.3%, 74.6%, 79.2%, 80.1% on average were realized under R of 200%, 250%, 300%, 350%, respectively. Relatively long anoxic hydraulic retention time (7.2 h) promoted the utilization of easily biodegradable carbon source in influent and facilitated the occurrence of endogenous denitrification by heterotrophic denitrifying bacteria, which lowered the anoxic observed sludge yield to simplify the wasted sludge disposal. For practical application in rural areas, R of 250-300% was appropriate with respect to a comprehensive consideration.
机译:在这项工作中,提出了一种新型的综合缺氧/缺氧生物膜反应器,以处理低碳氮比的农村生活污水。主要研究了内部循环(R)对集成反应器缺氧区中预脱硝和生物量产生的影响,以挖掘效率和经济潜力。 98天的实验结果表明:在R为200%,250%,300%,350%的条件下,平均脱氮效率分别为69.3%,74.6%,79.2%,80.1%。相对长的缺氧水力停留时间(7.2小时)促进了进水中易生物降解碳源的利用,并促进了异养反硝化细菌发生内源性反硝化,这降低了缺氧观察到的污泥产量,从而简化了浪费的污泥处置。对于农村地区的实际应用,综合考虑,R为250-300%是合适的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号