首页> 外文会议>2013 IEEE ECCE Asia Downunder >A model for estimating grid side harmonics of matrix converter based bi-directional IPT systems
【24h】

A model for estimating grid side harmonics of matrix converter based bi-directional IPT systems

机译:基于矩阵变换器的双向IPT系统的电网侧谐波估计模型

获取原文
获取原文并翻译 | 示例

摘要

Matrix converter (MC) based bi-directional inductive power transfer (BD-IPT) systems are gaining popularity as an efficient and reliable technique with single stage grid integration as opposed to two stage grid integration of conventional grid connected BD-IPT systems. However MCs are invariably rich in harmonics and thus affect both power quality and power factor on the grid side. This paper proposes a mathematical model through which the grid side harmonics of MC based BD-IPT systems can accurately be estimated. The validity of the proposed mathematical model is verified using simulated results of a 3 kW BD-IPT system and results suggest that the MC based BD-IPT systems have a better power factor with higher power quality over conventional grid connected rectifier based systems.
机译:与传统的并网BD-IPT系统的两级电网集成相反,基于矩阵转换器(MC)的双向感应电力传输(BD-IPT)系统作为一种高效可靠的技术,具有单级电网集成,正日益普及。但是,MC总是富含谐波,因此会影响电网侧的电能质量和功率因数。本文提出了一个数学模型,通过该模型可以准确估计基于MC的BD-IPT系统的电网侧谐波。使用3 kW BD-IPT系统的仿真结果验证了所提出数学模型的有效性,结果表明,基于MC的BD-IPT系统具有比传统的并网整流器系统更高的功率因数和更高的电能质量。