首页> 外文会议>2013 IEEE 5th International Symposium on Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications >Measurement and analysis of power frequency magnetic field in substation of Jing-Shi Passenger Railway Line
【24h】

Measurement and analysis of power frequency magnetic field in substation of Jing-Shi Passenger Railway Line

机译:京石客运专线变电站工频磁场的测量与分析

获取原文
获取原文并翻译 | 示例

摘要

In this paper, on the basis of the power frequency magnetic field data measured in substation, first, the test data analysis is given, then the overall distribution characteristics of power frequency magnetic field in substation is given. Reference the judge basis(DL/T 799.7-2002) of power frequency magnetic field intensity in substation work sites, the environment of power frequency magnetic field in substation is estimated, which showed that the intensity of power frequency magnetic field is in the permission range under a special industrial environment.
机译:本文基于变电站工频磁场数据,首先给出了测试数据分析,然后给出了变电站工频磁场的总体分布特征。参照变电站工作场所工频磁场强度的判断依据(DL / T 799.7-2002),估算了变电站工频磁场的环境,表明工频磁场的强度在允许范围内。在特殊的工业环境下。