An increased penetration of distributed energy sources for example photovoltaics (PV) leads to new challenges regarding supply of buildings. Besides the common used supply by the public distribution network (large scale generators, transformers) the islanded supply of buildings becomes feasible. Apart from the advantage of a multivalent up to a fully independent power supply in low-voltage distribution systems, questions regarding the functionality of commonly used overcurrent protection devices occur, because of a low short circuit power of the distributed power generators and a too high loop impedance, which is load and time depending. Furthermore the established measurement procedure of the fault loop impedance has to be verified for application in islanded networks with non-linear sources (e.g. inverters).
机译:分布式能源(例如光伏(PV))的普及率不断提高,导致建筑物供应面临新的挑战。除了公共配电网(大型发电机,变压器)的常用供应之外,孤岛式建筑物的供应也变得可行。除了在低压配电系统中使用多价高达完全独立的电源的优势外,由于分布式发电机的短路功率低且回路过高,还会出现有关常用过流保护装置功能的问题。阻抗,这取决于负载和时间。此外,必须验证已建立的故障环路阻抗测量程序,以用于具有非线性源(例如逆变器)的孤岛网络。