This paper presents a new approach to evaluate the efficiency of surge protective devices (SPD) for the protection against lighting as applied on the electrical power systems of wind turbine generators (WTG). The parameters of the performance of the SPDs which are considered to be critical for this application are their lifetime and voltage protection level at the power input point of the equipment. In this paper a method is presented to determine the lifetime of a SPD component based on the estimation of its exposure to currents due to direct lightning on the WTG over its lifetime using a statistical analysis of the lightning currents that could strike on a WTG and a distribution analysis of the lightning current in the WTG's electrical and grounding system. A lifetime test procedure for SPDs is suggested followed by an experimental verification test. Moreover, the voltage protection level at the equipment power input point is considered and a test procedure is also proposed to measure the effective voltage protection level using several expected voltage and current waveforms. Experimental results are presented to demonstrate the dependence of the voltage protection level on the SPD technology, installation configuration and equipment input impedance. The same approach could also be used in other application areas of SPDs, provided that the corresponding test procedures are adapted to the specific requirements of each application.
机译:本文提出了一种评估电涌保护器(SPD)的效率的新方法,该保护器可用于风力发电机(WTG)的电力系统中以防雷击。被认为对此应用至关重要的SPD性能参数是其寿命和设备电源输入点的电压保护等级。在本文中,提出了一种方法来确定SPD组件的寿命,该方法基于对在WTG上可能发生的雷电电流的统计分析,估算了WTG在其寿命期间由于直接雷击而在WTG上受到的电流影响。 WTG电气和接地系统中雷电流的分布分析。建议使用SPD的寿命测试程序,然后进行实验验证测试。此外,考虑了设备电源输入点的电压保护等级,并提出了一种测试程序,以使用多个预期的电压和电流波形来测量有效电压保护等级。实验结果表明,电压保护水平对SPD技术,安装配置和设备输入阻抗的依赖性。只要相应的测试程序适合每个应用程序的特定要求,则在SPD的其他应用领域中也可以使用相同的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号