Over-voltage triggering of a spark gap enables a synchronized operation of several Marx generators in repetitive operation without an increased wear of the electrodes. The trigger pulses are generated by means of a pulse generator consisting of several stacked stages, which are equipped with IGBTs as opening switches. A pulse transformer serves as intermediate energy storage. It replaces one charging coil between the first and second stage of the Marx generator and couples the trigger pulses into the Marx circuit causing an over-voltage across the 1st stage's spark gap. The number of stages of the trigger generator can be varied in order to adapt the trigger generator to different Marx generator designs with varying stray capacitance and breakdown voltage of the spark gap. The paper describes the design of the trigger generator and presents the results of tests.
机译:火花隙的过电压触发可在重复运行中使多个Marx发电机同步运行,而不会增加电极的磨损。触发脉冲由一个脉冲发生器产生,该脉冲发生器由几个堆叠的级组成,这些级配有IGBT作为断开开关。脉冲变压器用作中间能量存储。它替换了马克思发生器第一级和第二级之间的一个充电线圈,并将触发脉冲耦合到马克思电路中,从而在第一级的火花隙上产生了过电压。触发发生器的级数可以改变,以使触发发生器适应具有变化的杂散电容和火花隙的击穿电压的不同的马克思发生器设计。本文介绍了触发器生成器的设计并介绍了测试结果。