Partial discharge (PD) under a sequence of high-frequency pulse is one of the key factors which lead to premature failure of turn insulation of inverter-fed motors. Aging experiments for turn insulation samples under bipolar continuous square impulse voltage were done. The number and mean quantity of PDs under impulse voltage has been studied. By means of scanning electron microscope (SEM), the microcosmic morphology of surface of turn insulation was analyzed. The results reveal that the relationship of PD parameters (PD number and mean PD quantity) and aging time is complicated. The damage to polyimide nano-composite film structure is concentrated on the degradation of polymer matrix in the presence of PDs. The residual nano-fillers remained on the surface and formed a screen layer to resist the further damage of PDs. It is the symbol of faults expanding rapidly when the floccules and voids formed on the surface, which means insulation failure.
机译:高频脉冲序列下的局部放电(PD)是导致变频调速电机匝间绝缘过早失效的关键因素之一。对双极性连续平方脉冲电压下的匝间绝缘样品进行了老化实验。研究了脉冲电压下PD的数量和平均数量。借助扫描电子显微镜(SEM),分析了匝间绝缘表面的微观形态。结果表明,PD参数(PD数和平均PD量)与老化时间之间的关系复杂。在PDs的存在下,聚酰亚胺纳米复合膜结构的破坏集中在聚合物基质的降解上。残留的纳米填料保留在表面上并形成了屏蔽层以抵抗PD的进一步破坏。当表面上形成絮状物和空隙时,故障迅速扩展的标志,这意味着绝缘失效。