首页> 外文会议>2011 First International Conference on Instrumentation, Measurement, Computer, Communication and Control >Error Analysis of High-moisture Maize Moisture Measurement with PM-8188 Grain Moisture Tester
【24h】

Error Analysis of High-moisture Maize Moisture Measurement with PM-8188 Grain Moisture Tester

机译:用PM-8188谷物水分测定仪测量高水分玉米水分的误差分析

获取原文
获取原文并翻译 | 示例

摘要

PM-8188 type capacitance grain moisture tester was used to detect the moisture of twenty-four maize hybrids in the period of harvest time and the period when the grain were naturally fully dehydrated, the results were compared with the results of grain weight change, and the changes of measurement errors in high moisture levels were discussed briefly. The results showed that the measurement error reached its minimum by the measured value of 26.2. The measured value was larger than the true value when below 26.2, but smaller when exceeded. And the measurement error increased with the deviation from 26.2.
机译:使用PM-8188型电容式谷物水分测试仪来检测二十四个玉米杂种在收获期和谷物自然完全脱水期间的水分,并将其结果与谷物重量变化的结果进行比较,并简要讨论了高水分含量下测量误差的变化。结果表明,测量误差达到最小,达到26.2。低于26.2时,测量值大于真实值,但超过时,则小于真实值。并且测量误差随着与26.2的偏离而增加。