首页> 外文会议>2001 conference of Waste Management (WM);Annual Waste Management Symposium >PROTECTING NORTHWEST STAKEHOLDERS FROM HANFORD’S TANK WASTE
【24h】

PROTECTING NORTHWEST STAKEHOLDERS FROM HANFORD’S TANK WASTE

机译:保护汉福德坦克废物中的西北利益相关者

获取原文

摘要

Hanford's 177 tanks are located twelve to fifteen miles from the Columbia River, in southeasternWashington State. Currently, Hanford's tanks contain about 53 million gallons of highlyradioactive and chemically hazardous waste. Sixty-seven of Hanford's tanks have leaked anestimated one million gallons of this waste into the soil. Further releases to the ground, groundwater and the Columbia River are the inevitable result of tank failure. The contamination alreadyin ground water under Hanford could reach the Columbia River in as little as 20 years andcontinue for the next 5,000 years. The risk from this waste is recognized as a threat to theNorthwest as a region.Construction and operation of a Treatment Complex is the only viable permanent solution toreducing the risk posed by this tank waste. All other Federal sites with liquid high-levelradioactive and chemically hazardous waste have treatment facilities, but at Hanford the processto remove and treat the tank wastes is barely underway. There is now general agreement aboutthe right treatment method for Hanford tank waste - 'vitrification' or immobilizing tank waste byturning it into a glass - but serious concerns exist about the Federal government's ability to fund atreatment complex for Hanford.The Washington State Department of Ecology (Ecology) supports the vitrification of Hanfordtank waste; it is a technically sound and viable approach. Efforts to secure the necessaryfacilities have seen repeated false starts and delays over the past ten years. The most recentsetback , in summer of 2000, was the failed privatization approach to contracting. In late 2000,United States Department of Energy (USDOE) has shown commitment towards a TreatmentComplex by issuing a construction contract. Successful removal and treatment of Hanford's tankwaste will take at least thirty years and require a national commitment equivalent to that spentputting a man on the moon.Time is running out for Hanford's tanks. Continued storage of an enormous volume ofdangerous waste in Hanford's leaking and aging tanks poses catastrophic risks to the human,environmental and economic health of the Pacific Northwest. Failure to retrieve and treat thewaste is not an option. Washington State is willing to do whatever is necessary to ensureacquisition of a treatment complex for tank waste - succeeds this time around. We must all worktogether to make the present approach succeed.Washington State is seeking enforceable commitments that will hold the USDOE accountable,and ensure swift action to protect the environment, human health and the Columbia River.Washington State is also working to inform stakeholders about this regional problem – throughregular status reports and building a Pacific Northwest consensus and outcry for a Tank WasteTreatment Complex. Ecology is working with Congress to ensure adequate funds the project.
机译:汉福德的177辆坦克位于华盛顿州东南部,距离哥伦比亚河12至15英里。目前,汉福德的水箱包含约5300万加仑的高放射性和化学危险废物。汉福德(Hanford)的坦克中有67个泄漏了估计有100万加仑的废物进入土壤。储罐故障的必然结果是进一步释放到地面,地下水和哥伦比亚河。汉福德(Hanford)下的地下水中的污染可能会在短短20年内到达哥伦比亚河,并在接下来的5,000年内持续。废物产生的风险被认为是对西北地区的威胁。处理场的建设和运营是唯一可降低该废物产生风险的永久解决方案。所有其他具有液态高放射性和化学危险废物的联邦工厂均设有处理设施,但在汉福德,去除和处理储罐废物的过程几乎没有进行。如今,对于汉福德储罐废物的正确处理方法已经达成了普遍共识,即``玻璃化''或通过将其变成玻璃来固定储罐废物-但对于联邦政府为汉福德储集处理设施提供资金的能力存在严重担忧。华盛顿州生态部(生态学)支持汉福德坦克废物的玻璃化;这是一种技术上合理且可行的方法。在过去的十年中,为确保必要的便利所做的努力屡屡出现错误的开端和延误。最近一次的挫折发生在2000年的夏天,这是失败的私有化承包方式。 2000年底,美国能源部(USDOE)通过签发建筑合同表明了对TreatmentComplex的承诺。汉福德坦克的废物的成功清除和处理将至少需要30年,并且需要国家承担相当于将一个人送上月球的国家承诺。汉福德坦克的时间已经不多了。在汉福德泄漏和老化的储罐中继续储存大量危险废物,对西北太平洋地区的人类,环境和经济健康构成了灾难性风险。无法回收和处理废物不是一种选择。华盛顿州愿意采取一切必要措施,确保收购坦克废物处理综合设施-这次成功了。我们都必须共同努力,以使目前的方法取得成功。华盛顿州正在寻求可执行的承诺,这将使USDOE承担责任,并确保迅速采取行动保护环境,人类健康和哥伦比亚河。华盛顿州也在努力向利益相关者告知这一点。区域问题–通过定期状态报告,以及建立西北太平洋地区的共识并强烈抗议Tank WasteTreatment Complex。生态正在与国会合作,以确保该项目有足够的资金。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号