We present a method for corresponding and combining cartilage thickness readings from a population of patients using the underlying bone structure as a reference. Knee joint femoral bone and cartilage surfaces are constructed from a set of parallel slice segmentations of MR scans. Correspondence points across a population of bone surfaces are defined and refined by minimising an objective function based on the Minimum Description Length of the resulting statistical shape model. The optimised bone model defines a set of corresponding locations from which 3D measurements of the cartilage thickness can be taken and combined for a population of patients. Results are presented for a small group of patients demonstrating the feasibility and potential of the approach as a means of detecting sub-millimetre cartilage thickness changes due to disease progression.
机译:我们提出了一种方法,使用底层的骨结构作为参考,用于从一组患者中对应并组合软骨厚度读数。膝关节股骨和软骨表面由MR扫描的一组平行切片分段构成。通过基于所得统计形状模型的最小描述长度来最小化目标函数,可以定义和完善整个骨表面上的对应点。优化的骨骼模型定义了一组相应的位置,可以从中获取软骨厚度的3D测量值并将其组合用于一组患者。为一小部分患者提供了结果,证明了该方法的可行性和潜力,可作为检测由于疾病进展而导致的亚毫米软骨厚度变化的一种方法。