Protecting a future HVDC network from short circuit DC faults is presently expected to require extensive implementation of fast HVDC circuit breakers, allowing for rapid fault isolation. The requirement for circuit breakers may, however, be reduced or removed depending on the protection methodology, resulting in a slower post-fault recovery. The expected fault response and the subsequent network recovery is dependent on the circuit breaker, network, and converter configurations. This paper examines a low speed protection methodology for a symmetrical monopolar HVDC system, a configuration which requires pole to pole balancing following a pole to ground fault. The fault clearance and network recovery timings are therefore evaluated for both pole to pole and pole to ground faults on several case study networks.
机译:目前,保护未来的HVDC网络免受短路DC故障的影响,要求广泛实施快速HVDC断路器,以实现快速的故障隔离。但是,根据保护方法的不同,可以减少或消除对断路器的需求,从而导致故障后恢复速度变慢。预期的故障响应和后续的网络恢复取决于断路器,网络和转换器的配置。本文研究了对称单极高压直流输电系统的低速保护方法,该配置要求在极对地故障后需要极对极平衡。因此,在几个案例研究网络中,对极对极和极对地故障都评估了故障清除和网络恢复的时间。