首页> 外文会议>10th International Symposium on Tubular Structures; Sep 18-20, 2003; Madrid, Spain >Full-scale testing of beam-to-column connections with partial joint penetration groove welded joints
【24h】

Full-scale testing of beam-to-column connections with partial joint penetration groove welded joints

机译:用部分接头穿透槽焊接接头进行梁到柱连接的全面测试

获取原文
获取原文并翻译 | 示例

摘要

This paper concerns the applicability of partial joint penetration (PJP) groove welds for beam-to-column connections. Two full-sized beam-to-column connections with PJP groove welds at the ends of the beam bottom flanges were tested under cyclic loads. When the unfused regions created by PJP groove welds were reinforced by fillet welds so that the welded joints have a sufficient cross-sectional area, ductile cracks grew stably and, in consequence, the connections showed sufficient deformation capacity. Test results were reproduced well by non-linear FE analyses. Strains sustained at points around internal discontinuities were found to be low because of greater cross-sectional areas of welded joints compared with the cross-sectional area of the beam flanges. Fracture toughness properties of numerically modelled connections were evaluated by using a recently developed fracture mechanics approach. Both the test results and the fracture mechanics based assessment demonstrated that it is unlikely to initiate brittle fracture at these discontinuities.
机译:本文涉及部分对焊(PJP)坡口焊缝在梁到柱连接中的适用性。在循环载荷下测试了两个全尺寸的梁到柱连接,在梁底部法兰的末端带有PJP坡口焊缝。当通过PJP坡口焊缝形成的未熔合区域通过角焊缝进行加固,使焊接接头具有足够的横截面积时,延性裂纹会稳定增长,因此,连接处显示出足够的变形能力。通过非线性有限元分析可以很好地再现测试结果。发现在内部不连续点附近维持的应变较低,因为与梁法兰的横截面相比,焊接接头的横截面面积更大。通过使用最新开发的断裂力学方法评估了数值模型连接的断裂韧性。测试结果和基于断裂力学的评估均表明,在这些不连续处不太可能引发脆性断裂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号